ARM9511-M DIN Rail Relay Control Energy Meter
ARM9511-M / ARM9513-M are DIN Rail Relay Control Energy Meter can accurately and directly measure energy consumption and billing. The meters have Relay function, support to control the switch (on/off) remotely. It can Max. support Max. 80A direct input. With Modbus-RTU protocol and RS485 port, the meter also supports connect into 3rd party system.
Product Description
Features
- Suit for 120V, 220V, 230V, 240VAC Power System
- 7+1 digits LCD display (9999999.9kWh)
- High accuracy: Class 0.5s for 5A via CT, Class 1.0 for 80A direct input
- 3 keys for programming, 35mm DIN Rail installation, standard DIN ED5002
- 1 LED indicates pules output, standard DIN 43864
- Support reading and inquiry data when power off
- Standard: IEC62053-21/22
Functions
- Measure – U, I, P, Q, S, PF, F, kWh, kvarh, multi-tariff energy (kWh, kvarh)
- Relay Control – for remote control circuit switch on/off
- TOU (Multi-tariff) – 4 tariffs and 8 time periods in 24 hours Historical Record – kWh, kvarh, Max. P for last 31 days (Per 15min) and last 12 months data; last 200 alarms and last 20 times power off Alarm — temper alarm, switch on/off alarm, over-voltage alarm, under-voltage alarm, reversed connection alarm etc.
- Communication – one RS485 port, MODBUS-RTU Protocol
Technical Specifications
Accuracy | Class 0.5s: 5 (6) A
Class 1.0: 10 (80)A |
Rated Current | ARM9511-M/ARM9513-M: Class 1.0: 10 (80)A
ARM9513-M: 5(6)A via CT |
Rated Voltage (Optional) | ARM9511-M: 120V, 220V, 240V
ARM9511-M: 120/208V, 220380V, 240/415V |
Power Supply | Self Supply (Note: for ARM9513-M, RS485 won’t work if only connect 1 phase voltage)
Overload: 1.2 times |
Relay Control | Support control circuit switch on/off
For ARM9511-M: Build-in relay module For ARM9513-M (80A): Build-in Relay module For ARM9513-M (5A): Need to add AC contactor Need to add AC Contactor and Relay Switch |
Pulse Output | 1 Channel (Settable for kWh or kvarh)
constant: 1600imp/kWh/kvarh Wet contact, power supply range: 5~30VDC |
Frequency | 50/60Hz |
Power Consumption | <2W/10VA each phase |
Wire Diameters | 7mm*7mm (16mm2) |
Starting Current | 0.4% lb |
Communication | RS485 port, MODBUS-RTU
Baud rate: 2400、4800、9600 Address: 1~247 |
Insulation | Withstand voltage: 2kV, Impulse voltage:6kV |
Historical Record | kWh, kvarh, Max. P for last 31 days (Per 15min.) and last 12 months data
last 200 alarms records last 20 times power off |
Alarm | Temper alarm
Switch on/off alarm Over-voltage alarm Under-voltage alarm Reversed connection alarm |
EMC Standard | Electrostatic discharge immunity test IEC61000-4-2, Level 4
Radiated immunity test IEC61000-4-3, Level 3 Electrical fast transient/burst immunity test IEC61000-4-4, Level 4 Surge immunity test (1, 2/50μs ~ 8/20 μs) IEC61000-4-5, Level 4 Conducted emission EN55022, Class B Radiated emission EN55022, Class B |
Environment | Operating temperature: -20°C ~ +55°C
Storage temperature: -40°C ~ +70°C Humidity: 5% ~ 95% non-condensing |